title: What is the minimum measurement time? [Moisture Analyzers] [MS/MX/MF/ML]
description: It depends on the material and moisture content, but because MS/MX/MFML incorporates 400W halogen lamp as the heating source
---

[Skip to content](https://support.aandd.co.jp/en/faq/what-is-the-minimum-measurement-time#main-content)

English

Show submenu for translations

![](https://support.aandd.co.jp/hs-fs/hubfs/A%26D%20DiscoverPrecisionLogo-White-RGB.png?width=100&height=75&name=A%26D%20DiscoverPrecisionLogo-White-RGB.png)

- [Frequently Asked Questions](https://support.aandd.co.jp/en/faq)

Open main navigation

Close main navigation

- [Frequently Asked Questions](https://support.aandd.co.jp/en/faq)
- English
  
  Show submenu for translations
- [Home](https://global.aandd.jp/)

[Home](https://global.aandd.jp/)

 Frequently Asked Questions

- There are no suggestions because the search field is empty.

1. [Frequently Asked Questions](https://support.aandd.co.jp/en/faq?hsLang=en)
2. [Test & Measurement](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en)
3. [Moisture Analyzer](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en#moisture-analyzer)

# What is the minimum measurement time? \[Moisture Analyzers\] \[MS/MX/MF/ML\]

It depends on the material and moisture content, but because MS/MX/MFML incorporates 400W halogen lamp as the heating source, the pan can be heated from ambient temperature to 200C in only 2 minutes. Also, since an SHS sensor designed for analytical balances is installed, the sensing of the weight of the sample before and after heating is precise and thus requires less sample volume than before. With an appropriate heating temperature and sample mass, measurement can generally be completed within a few to 20 minutes.  
Therefore, for the following reasons MS/MX/MF/ML’s heating time and thus also measurement time are shortened.

1. Heating to a set temperature is fast
2. Only a very little quantity of sample is needed for measurement.

- [Balance / Scale](https://support.aandd.co.jp/en/faq/balance-scale?hsLang=en#main-content)

    - [Software](https://support.aandd.co.jp/en/faq/balance-scale?hsLang=en#software)
    - [Analytical Instruments](https://support.aandd.co.jp/en/faq/balance-scale?hsLang=en#analytical-instruments)
    - [Balance](https://support.aandd.co.jp/en/faq/balance-scale?hsLang=en#balance)
- [Test & Measurement](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en#main-content)

    - [Electronic Pipette](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en#electronic-pipette)
    - [AD7011-EVA](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en#ad7011-eva)
    - [Moisture Analyzer](https://support.aandd.co.jp/en/faq/test-measurement?hsLang=en#moisture-analyzer)
- [General Purpose Digital Measurement Equipment](https://support.aandd.co.jp/en/faq/general-purpose-digital-measurement-equipment?hsLang=en#main-content)

    - [General Purpose Digital Measurement Equipment](https://support.aandd.co.jp/en/faq/general-purpose-digital-measurement-equipment?hsLang=en#general-purpose-digital-measurement-equipment)
- [Home Healthcare](https://support.aandd.co.jp/en/faq/home-healthcare?hsLang=en#main-content)

    - [Blood Pressure Monitor](https://support.aandd.co.jp/en/faq/home-healthcare?hsLang=en#blood-pressure-monitor)
- [Telemedicine](https://support.aandd.co.jp/en/faq/telemedicine?hsLang=en)

[Home](https://global.aandd.jp/)

Copyright © 2025 A&D Company, Limited